Southwire 21010N 10/2 NM-B Cable 250 Ft – Reliable Indoor Electrical Wire for Home Wiring Projects
The Southwire 21010N is a coil of 10/2 NM-B nonmetallic sheathed cable with ground, which is a long way of saying it holds two 10-gauge copper conductors plus a bare equipment ground, all wrapped in a tough outer jacket and sold for interior wiring work. Electricians call this stuff "Romex" out of habit, even though that is a brand name from a different manufacturer, and homeowners usually just call it "the orange wire" once they see it on the shelf. Either way, this is the cable you reach for when a circuit needs more muscle than a standard 15- or 20-amp branch line can deliver.
What makes the 21010N worth understanding before you buy it is the ampacity math behind that 10-gauge copper. Ten AWG is the smallest conductor size that comfortably handles 30 amps, which opens the door to water heaters, baseboard heaters, air conditioner condensers, workshop tools, and subpanel feeds. Get the gauge, the cable type, or the installation rules wrong and you will fail an inspection, waste a hundred dollars on the wrong spool, or create a genuine fire hazard. The details below cover what the cable actually is, where it belongs, and how to install it so it holds up for decades.
What the Southwire 21010N Actually Is
Southwire is one of the largest wire and cable manufacturers in North America, and the 21010N sits in their NM-B product family. NM stands for nonmetallic sheathed, and the B suffix indicates the improved 90-degree C insulation that replaced the older NM-C designation decades ago. The cable is listed by Underwriters Laboratories and manufactured to meet the requirements of Article 334 in the National Electrical Code, which is the section that governs how this type of cable must be used.
If you buy the 21010N, expect a coil wrapped in plastic with the conductor size, voltage rating, and cable type printed repeatedly along the jacket. Those printed markings matter more than most shoppers realize, because inspectors check them to confirm the cable is listed and rated for the application. You will typically find this product sold in 100-foot and 250-foot coils, though exact packaged lengths vary by retailer and regional distribution. Copper is priced by weight and moves with the commodities market, so the same coil can cost noticeably more or less from one month to the next.
Core Specifications at a Glance
The two current-carrying conductors are both 10 AWG stranded or solid copper, depending on the production run, and they are insulated in black and white. The grounding conductor is a bare copper conductor of the same gauge, which is a meaningful detail: the ground is not insulated, so it counts differently in box-fill calculations than the two wrapped conductors do. The finished cable is rated for 600 volts nominal, which is far above anything a residential panel will ever throw at it.
The insulation on the individual conductors carries a 90-degree C rating, which trips up a lot of do-it-yourselfers. That rating applies to the insulation material itself, not to the ampacity you are allowed to use. Per NEC 334.80, NM-B cable must be sized using the 60-degree C column of the ampacity table, and for 10 AWG copper that means a maximum of 30 amps in typical residential work.
| Attribute | Specification |
|---|---|
| Conductor size | 10 AWG copper |
| Conductors | Two insulated (black, white) plus bare copper ground |
| Cable type | NM-B, nonmetallic sheathed |
| Voltage rating | 600 volts |
| Insulation temperature | 90 degrees C insulation, ampacity per the 60 degrees C column |
| Approved locations | Dry, interior locations |
| Common packaging | Coiled lengths, frequently 100 ft or 250 ft |
One practical note on appearance: Southwire color-codes the outer jackets across their NM-B line, with white for 14-gauge, yellow for 12-gauge, and orange for 10-gauge in most residential products. The orange jacket is genuinely useful on a job site because you can tell at a glance which cable is the heavier 30-amp wire without reading the print.
How NM-B Cable Is Built
Underneath that jacket you will find two insulated conductors lying parallel, with the bare ground positioned between or alongside them. Most NM-B products also include a thin paper separator wrapped around the conductors to keep the jacket from bonding to the insulation during extrusion. That separator is one of the reasons the jacket slides off so cleanly when you score it with a knife.
The outer jacket is a tough, flame-retardant PVC compound that resists abrasion and moisture vapor, though it is not waterproof and it is not a substitute for conduit in wet or corrosive environments. Because the ground is bare and the conductors are tightly packed, NM-B has a low profile that pulls easily through drilled framing and staples neatly along the sides of studs. Its flexibility is why it dominates residential wiring in the United States while commercial projects tend to favor metal-clad cable or conductors pulled through conduit.
Where 10/2 NM-B Earns Its Keep
A 30-amp circuit is the sweet spot for a long list of household loads, and 10/2 is the cheapest, easiest way to feed most of them. The cable carries 240 volts when both the black and white conductors are used as ungrounded conductors, which is exactly how a water heater, a wall heater, or an air conditioner condenser is wired. In that configuration, the bare copper handles the equipment grounding job and no neutral is needed.
Voltage drop is the other reason people step up to 10-gauge even when a 12-gauge circuit would technically satisfy the code. On a long run out to a detached shop or a pool pump, the extra copper keeps the voltage at the equipment within a few percent of nominal, which protects motors from running hot and failing early. Ten-gauge over a 100-foot run loses far less voltage than 12-gauge over the same distance, and that difference is often the deciding factor in equipment performance.
Typical 30-Amp Loads
Electric water heaters are probably the single most common application. A standard residential tank-style heater draws 4,500 watts at 240 volts, which works out to roughly 19 amps, and 10/2 with a 30-amp breaker handles it with plenty of headroom. Fixed electric baseboard heaters, wall-mounted shop heaters, and small resistance heating circuits follow the same pattern.
Air conditioner condensers, well pumps, dust collectors, table saws, and welder receptacles also show up on 10/2 circuits regularly. There is one important exception worth flagging: an electric clothes dryer almost always needs 10/3 rather than 10/2, because the dryer motor, timer, and light run on 120 volts and therefore require a neutral conductor in addition to the two hots and the ground. If you are wiring a dryer, buy 10/3 and save yourself a second trip to the store.
Where It Should Never Go
NM-B is restricted to dry, protected locations, and the code is not subtle about it. You cannot bury it directly in the ground, run it outdoors, install it in a damp or wet location, or embed it in poured concrete or masonry. It does not belong inside conduit in a wet environment either, and it is prohibited in commercial garages, hazardous locations, and the plenum spaces of most commercial buildings.
Roof cavities, attics near exhaust fans, and underslab runs all disqualify it for one reason or another. If your project touches any of those conditions, the alternatives are direct-burial UF-B cable, metal-clad cable, or individual conductors pulled through conduit. Local amendments occasionally tighten these rules further, so a quick check with your inspection authority is worth the phone call before you commit to a design.
Installation Practices That Keep Inspectors Happy
Securing the cable properly is the first thing an inspector looks at. NM-B must be supported within 12 inches of every box and every 4.5 feet along its run, using staples or straps rated for the cable's width. Drive staples snug but not tight enough to dent the jacket, because deformed insulation is exactly the kind of damage the supporting rules exist to prevent.
Running through wood framing requires holes drilled at least 1-1/4 inches from the nearest edge of the stud, or protection with a steel nail plate where the hole falls short of that distance. Keep holes centered in the stud's width and bore them slightly larger than the cable so it slides instead of dragging. Sharp bends are another failure point, so respect the minimum bend radius of about five times the cable diameter and never fold it back on itself.
Stripping, Terminating, and Handling Copper
Score the outer jacket lengthwise with a utility knife held at a shallow angle, then peel it back rather than cutting all the way around. The goal is to expose the conductors without nicking them, since a sliced conductor creates a hot spot that can fail years later. Roughly eight to ten inches of jacket removed at a box gives you enough conductor to make up the splice and fold the wires neatly.
When both insulated conductors are used as hot legs on a 240-volt circuit, the white conductor must be permanently re-identified at both ends with black or red tape, heat-shrink, or marker. Torque breaker and receptacle terminals to the values printed on the device, and use the correct cable clamp or connector at every box entry. NM-B does not require anti-short bushings the way armored cable does, which simplifies terminations considerably.
Buying Smart and Comparing Alternates
Coil length drives the price more than anything else, so measure your run before you shop and add a generous margin for routing, waste, and future service loops. Buying a 250-foot coil for a 90-foot run leaves you storing leftover cable, while buying two 100-foot coils for a 180-foot job often costs more per foot than the larger single coil. Also confirm the cable is solid copper rather than copper-clad aluminum, since the two look similar from a distance and the aluminum version is not interchangeable in most residential terminations.
If the circuit needs a neutral, step up to 10/3 NM-B. If the run is underground or outdoors, switch to UF-B. If the installation is commercial or exposed in a hard-use environment, metal-clad cable or conduit-protected THHN is the right call. Matching the cable type to the environment is what separates a passing inspection from a callback, and it costs very little to get right the first time.
Whether you are feeding a water heater in a basement or pulling a dedicated circuit to a garage compressor, the Southwire 21010N is a dependable, widely stocked option that does its job quietly for decades. Check the printed jacket markings, plan your route before you drill the first hole, and leave the box covers off until the inspector has had a look. The best wiring job is the one nobody ever has to think about again.