10/2 UF Wire: The Ultimate Guide to Underground Feeder Cable
If you’re planning to run power to a detached garage, well pump, or outdoor outlet, the phrase “10/2 UF wire” probably popped up in your search. It’s one of the most common cables for underground and wet-location wiring, but it’s also easy to buy the wrong version or install it in a way that fails inspection. Understanding what the label means, where it’s allowed, and how to size the circuit will save you time, money, and a lot of digging.
UF stands for Underground Feeder, and 10/2 describes the wire itself: 10 AWG copper conductors and two insulated current-carrying wires. Most modern 10/2 UF cable also includes a bare equipment ground, which is why it’s often sold as 10/2 UF-B with ground. That combination makes it a rugged, moisture-resistant choice for direct burial, but it is not a universal replacement for every indoor cable.
What Is 10/2 UF Wire?
10/2 UF wire is a type of electrical cable designed for underground feeders and wet locations. The conductors are solid or stranded copper, depending on the manufacturer, and the entire assembly is wrapped in a tough, sunlight-resistant jacket. UF-B is the most common designation you’ll see on store shelves today, and it improves on older UF cable with better moisture and heat resistance.
The key difference between UF and standard NM-B Romex is the jacket. NM-B is meant for dry, indoor locations and cannot be buried or exposed to moisture. UF cable is built to sit in soil, run through outdoor conduit, or feed equipment in damp environments. Its gray jacket usually signals that it is suitable for direct burial, though you should always check the printed markings on the cable.
Decoding the 10/2 Label
The “10” in 10/2 UF wire refers to the American Wire Gauge size of the conductors. In AWG, smaller numbers mean larger wires, so 10 AWG is thicker than 12 AWG or 14 AWG. That extra copper gives it a higher current-carrying capacity, which is why 10-gauge wire is commonly used for 30-amp circuits.
The “2” means there are two insulated conductors inside the cable. In a typical 120/240-volt setup, those are often a black hot wire and a white neutral wire. If you use the white wire as a hot conductor for a 240-volt load, code requires you to re-identify it with black or red tape at both ends. The bare copper ground wire, when present, is not counted in the “2,” but it is essential for safety.
UF-B Construction and Ratings
A 10/2 UF-B cable is usually rated for 600 volts and listed for direct burial, wet locations, and sunlight exposure. The jacket is resistant to moisture, fungus, and corrosion, and it can handle the temperature swings that come with outdoor installations. These ratings are what separate it from cheaper indoor cable that would quickly deteriorate underground.
UF-B is also physically tough, but it is not indestructible. It still needs protection where it emerges from the ground, passes through a foundation, or risks being hit by lawn equipment. Many electricians sleeve the exposed ends in PVC conduit or metal raceway, and some jurisdictions require conduit for the entire run even when direct burial is allowed.
Where 10/2 UF Wire Is Used and How to Install It Safely
10/2 UF wire shows up in a wide range of outdoor projects. It can feed a 240-volt well pump, a 30-amp RV outlet, a detached shed circuit, or landscape lighting that needs a reliable underground path. Because it contains only two insulated conductors, it is best suited to a single 120-volt circuit or a 240-volt load that does not require a separate neutral.
Installation is where most mistakes happen. Direct-burial cable must be buried deep enough, protected where it leaves the ground, and connected to a properly sized breaker. Local codes can be stricter than the NEC, so check with your inspection authority before you dig. A permit and a quick call to 811 for utility locating are smart steps before any trench is opened.
Common Applications for 10/2 UF Cable
Submersible well pumps are one of the most common uses for 10/2 UF wire. A typical 240-volt pump may need two hot conductors and a ground, which 10/2 UF-B provides. The exact wire size depends on the pump’s full-load amps, the distance from the panel, and the voltage drop, so a 10-gauge cable is not automatically correct for every well.
Outdoor receptacles and small outbuildings are another frequent application. A 30-amp, 120-volt RV receptacle often uses 10/2 UF with ground, and a shed that only needs one 240-volt heater or a single 30-amp circuit can also use it. If you want both 120-volt and 240-volt power in a subpanel, you’ll usually need 10/3 UF instead because that requires an insulated neutral.
Ampacity, Voltage Drop, and Circuit Sizing
Ampacity is the maximum current a wire can carry safely under specific conditions. For 10 AWG copper, the common ampacity is 30 amps at 60°C, which matches many UF cable terminations and breakers. Some tables allow 35 amps at 75°C, but the final limit is set by the weakest link in the circuit: the breaker, terminals, and equipment nameplate.
Voltage drop matters just as much as ampacity on long underground runs. A 30-amp load at 240 volts can suffer noticeable voltage loss over 150 feet or more, and a 120-volt circuit is even more sensitive. In those cases, upsizing to 8 AWG UF or reducing the load may be necessary. Always calculate voltage drop before buying cable, because replacing an undersized direct-burial run is expensive and frustrating.
Burial Depth, Protection, and Code Basics
The National Electrical Code sets minimum burial depths for UF cable, but the exact number depends on the circuit and whether it is in conduit. Direct-buried cable generally requires 24 inches of cover, while some residential branch circuits with GFCI protection may be allowed at 12 inches. Conduit sleeving, driveway crossings, and areas under concrete have their own rules.
Where the cable rises out of the ground, it must be protected from physical damage. Schedule 80 PVC, rigid metal conduit, or another approved raceway is commonly used up to the box or disconnect. Outdoor receptacles also need GFCI protection in most cases, and all junctions must remain accessible inside approved enclosures. These details are not optional if you want the installation to pass inspection.
Tips for Buying and Handling 10/2 UF Wire
When shopping for 10/2 UF wire, confirm that the cable is UF-B and includes a ground conductor. Some listings use confusing labels, and older UF cable may not have the same ratings as modern UF-B. Look for printed markings such as “UF-B,” “direct burial,” “sunlight resistant,” and the AWG size. Buy from a reputable supplier so you know the cable meets UL or ETL standards.
UF cable is stiffer and harder to strip than indoor Romex, so use the right tools and take your time. A cable ripper or utility knife can score the jacket, but you must avoid nicking the copper conductors. Leave extra slack at both ends, seal conduit entries against water, and support the cable properly at terminations. Good workmanship is what keeps a direct-burial circuit reliable for decades.
When you’re ready to run power to a well pump, shed, or outdoor outlet, treat 10/2 UF wire as a system component, not just a roll of cable. Confirm the load, check voltage drop, follow burial depth rules, and have the work inspected where required. A little planning on the front end keeps the circuit safe, code-compliant, and ready for years of weather and wear.