what is mirror artifact in ultrasound

What is Mirror Artifact in Ultrasound: A Comprehensive Guide

By Brian Anderson
AD

Ever wondered about that strange, echoing effect sometimes seen in ultrasound images? That intriguing phenomenon is known as a mirror artifact.

In the realm of diagnostic imaging, artifacts are not necessarily undesirable; they are simply images that don't represent true anatomical structures. Instead, they reflect the limitations of imaging technologies, like ultrasound, to accurately depict specific tissue characteristics or boundary conditions.

The Physics Behind Mirror Artifacts

To understand mirror artifacts, let's delve briefly into the physics of ultrasound. During an ultrasound scan, high-frequency sound waves are emitted, bounce off organs and other tissues, and then return to the probe, creating an image.

AD
Mirror image artifact - kidney 'reflected in diaphragm Morrison Pouch Ultrasound, Liver Segments Ultrasound Radiopaedia, Normal Liver Ultrasound, Kidney Ultrasound Images, Liver Ultrasound Protocol, Liver Ultrasound Images, Kidney Ultrasound Results, Ultrasound Scan Of Fetal Development, Renal Ultrasound Image
Mirror image artifact - kidney 'reflected in diaphragm Morrison Pouch Ultrasound, Liver Segments Ultrasound Radiopaedia, Normal Liver Ultrasound, Kidney Ultrasound Images, Liver Ultrasound Protocol, Liver Ultrasound Images, Kidney Ultrasound Results, Ultrasound Scan Of Fetal Development, Renal Ultrasound Image
Client Challenge
Client Challenge
an x - ray shows three arrows pointing to the right and left side of the chest
an x - ray shows three arrows pointing to the right and left side of the chest

Mirror artifacts occur when strong sound wave reflections, typically at high-impedance interfaces or air-tissue boundaries, result in little or no energy returning to the probe. This lack of return signal causes the machine to fill in the image with an echo - hence the term 'mirror' artifact.

High-Impedance Reflections

High impedance refers to how resistant an interface is to wave transmission. Tissues with high impedance, like bone, reflect most of the sound energy, causing a strong reflection. This strong reflection can mimic a mirror image of the structure behind it, leading to a mirror artifact.

Mirror Image Artifact
Mirror Image Artifact
Ultrasound Artifact
Ultrasound Artifact
Client Challenge
Client Challenge

The calvarium (skull) is a common source of high-impedance reflections in neurosonology. As sound waves travel through the soft tissue of the scalp and skull, they encounter sudden changes in density, causing strong reflections. If the ultrasound beam encounters another tissue interface on the far side of the skull, it can create a mirror image, mimicking a structure that's not actually there.

Air-Tissue Boundaries

Another setting where mirror artifacts often appear is where there's an air-tissue interface. Air, being an excellent sound reflector, can mimic a mirror image behind itself. This is why you might see mirror artifacts in ultrasound imaging of the lungs or the gastrointestinal system, where air-filled structures are common.

AD

A typical example is when the ultrasound probe is placed over the liver, near the diaphragm. Sound waves encounter the air-filled lungs, creating a strong reflection and generating a mirror artifact, giving the appearance of an additional liver lobe on the far side of the lungs.

Echo artifacts
Echo artifacts
Twinkling artifact: a key clue in ultrasound!
Twinkling artifact: a key clue in ultrasound!
three different views of the same area
three different views of the same area
four different types of round objects with the word boundary below them in grey and black
four different types of round objects with the word boundary below them in grey and black
the different types of mris are shown in this poster
the different types of mris are shown in this poster
two images show the same section of an animal's stomach, and one shows what is
two images show the same section of an animal's stomach, and one shows what is

Recognizing and Interpreting Mirror Artifacts

Recognizing a mirror artifact is crucial to avoid misdiagnosing a false structure. Typically, mirror artifacts appear as bright, well-defined, echoes that mimic actual anatomical structures. They often show up behind high-impedance tissues, like bone, or air-filled organs, and tend to remain stationary regardless of probe movement or patient positioning.

A skilled ultrasonographer can differentiate these artifacts by using various techniques, such as altering the ultrasonic beam angle, adjusting gain settings, or using posterior approaches to image the structure of interest.

AD

Angling the Beam

Changing the angle of the ultrasonic beam can help to avoid reflecting off high-impedance interfaces. If you can image the structure without a mirror artifact after changing the probe angle, it suggests that the structure is not real but an artifact.

an image of the inside of a breast with labels on it and labeled in red
an image of the inside of a breast with labels on it and labeled in red

For instance, if you're performing an ultrasound of the kidneys, try tilting the probe to image the kidney from a posterior approach rather than the traditional intercostal approach. If the structure disappears, it's likely a mirror artifact from the ribs.

Adjusting Gain Settings

Modulating the gain can also help distinguish artifacts. Reducing the gain might eliminate the echo, further suggesting it's not a true anatomical structure. However, be cautious not to reduce gain too much, as it can affect the quality of the entire image.

AD

Increasing the gain, conversely, can enhance a mirror artifact, making it more visible. This can sometimes be useful in confirming whether a suspected structure is indeed an artifact, as increasing gain usually doesn't change the appearance of a true anatomical structure.

Understanding and recognizing mirror artifacts is crucial for accurate ultrasound interpretation. While they can sometimes pose diagnostic challenges, they also offer opportunities for clinical investigation and serve as reminders of the intricacies of imaging technologies.

AD