polyiso r value per inch

Polyiso R Value Per Inch Explained: Maximize Insulation Efficiency

By Thomas Moore
AD

If you are comparing rigid foam insulation for a wall, roof, or attic project, the number you keep running into is polyiso R-value per inch. Polyisocyanurate boards pack more thermal resistance into every inch of thickness than almost any other commonly available insulation product, which makes them a favorite for continuous exterior insulation and low-slope roofing where space is tight. But the headline rating printed on the board is only part of the story, and understanding what that number actually represents will save you from undersizing an assembly or overspending on thickness you do not need.

This guide breaks down the realistic R-values you can expect from polyiso, how temperature, facers, and aging change those numbers, and how polyiso stacks up against XPS, EPS, spray foam, and mineral wool. By the end you should be able to read a manufacturer's data sheet, spot inflated claims, and choose the right board thickness with confidence.

Understanding Polyiso R-Value Per Inch

Polyiso is short for polyisocyanurate, a closed-cell thermoset plastic foam that is typically produced as a rigid board and laminated with a facer on both sides. At a mean temperature of 75 degrees Fahrenheit, most polyiso products deliver between R-5.6 and R-6.5 per inch of thickness. That range is not manufacturer sloppiness; it reflects real differences in blowing agents, foam density, facer type, and how long the board has been sitting in the warehouse before testing.

AD
Thermal Drift: R-Value Loss in Polyiso & XPS Foam Explained
Thermal Drift: R-Value Loss in Polyiso & XPS Foam Explained
New LTTR Values and What They Mean for Roofing Industry Professionals
New LTTR Values and What They Mean for Roofing Industry Professionals
Compare Insulation R-Values Before Building
Compare Insulation R-Values Before Building

The reason polyiso outperforms other rigid foams at moderate temperatures comes down to its cellular structure and the gas trapped inside those cells. The closed cells are filled with a low-conductivity blowing agent rather than plain air, and that gas is a major part of what makes the board insulate so well. Over time some of that gas diffuses out and air diffuses in, which is why standards require long-term thermal resistance, or LTTR, values rather than the inflated numbers you get from a brand new sample.

What Is Polyiso Insulation?

Polyisocyanurate is chemically related to polyurethane foam but formulated with a higher ratio of isocyanate, which improves fire performance and dimensional stability. The foam is poured between two facers, most commonly aluminum foil, but you will also see coated glass fiber, kraft paper, and foil-fiberglass combinations. The facer matters more than most buyers realize because it contributes to the board's moisture resistance, radiant barrier properties, and structural integrity.

Insulation R-Value Chart: Complete Guide to Every Material (2026)
Insulation R-Value Chart: Complete Guide to Every Material (2026)
All About Insulation R-Values | The Home Depot
All About Insulation R-Values | The Home Depot
Insulating Power: Testing for R-Value - Drexel Metals
Insulating Power: Testing for R-Value - Drexel Metals

Boards are sold in standard thicknesses of half an inch, three quarters of an inch, one inch, one and a half inches, two inches, two and a half inches, three inches, and four inches. Common applications include exterior continuous insulation on framed walls, tapered roof insulation systems on commercial buildings, cathedral ceiling assemblies, and insulated sheathing on above-grade walls. Because the facers can wick moisture, polyiso is generally not the first choice for below-grade foundation walls, where extruded polystyrene tends to be the safer pick.

The Rated R-Value You Will See on the Label

Manufacturers publish two numbers: an initial R-value and an LTTR value. The initial figure, often around R-6.5 per inch or higher, is measured shortly after production. The LTTR figure is measured after a period of aging and is what the FTC's R-value rule expects to be advertised for the product's intended service life. Most polyiso boards carry an LTTR of roughly R-5.6 to R-6.0 per inch, and that is the number you should use when calculating assembly performance for code compliance.

AD

You will usually find the LTTR stamped on the board edge, printed on the packaging, or listed in the manufacturer's technical data sheet under ASTM C1289, the standard specification for faced rigid cellular polyisocyanurate thermal insulation board. If a sales sheet only quotes an initial R-value with no LTTR, treat the claim with skepticism and ask for the aged number in writing.

a blue sign that says r - value explaining the potential for remodeling
a blue sign that says r - value explaining the potential for remodeling
R-Values for Insulation and Flooring Materials – iCork Floor
R-Values for Insulation and Flooring Materials – iCork Floor
Understanding R values and building performance
Understanding R values and building performance
the table shows the number and type of insulations for different types of materials, including insulation
the table shows the number and type of insulations for different types of materials, including insulation
insulation value chart for various types of insulations and their uses, including insulation insulation
insulation value chart for various types of insulations and their uses, including insulation insulation
a pile of different types of materials with the text r - value calculator
a pile of different types of materials with the text r - value calculator

Real-World Factors That Change Polyiso Performance

The polyiso R-value per inch you get in a real building rarely matches the lab number exactly. Two factors account for most of the gap: temperature and moisture. Polyiso's thermal conductivity rises as the mean temperature drops, which means a board that performs brilliantly in a 75 degree wall cavity in Atlanta behaves noticeably worse in a Minnesota attic in January. This is not a defect; it is a documented characteristic that codes and design guides account for in different ways.

Moisture is the second variable. Polyiso is closed-cell and resists bulk water well, but the facers and cut edges can absorb and retain water, and wet insulation loses thermal performance quickly. Proper detailing around penetrations, flashing, and end joints is what keeps the R-value you paid for intact over a twenty or thirty year service life.

AD

Temperature Dependence and Thermal Drift

Testing shows that polyiso's R-value per inch declines as the service temperature falls. At a mean temperature of 75 degrees, a typical board might sit near R-6.0 per inch. At 40 degrees that can slide to about R-5.2, at 25 degrees to roughly R-5.0, and at 0 degrees Fahrenheit some products drop into the R-4.5 range. At extreme cold, certain formulations have measured as low as R-4.0 per inch.

What R-Value Does Your Home Actually Need?
What R-Value Does Your Home Actually Need?
Polyiso Insulation Performance in Cold Climates - GreenBuildingAdvisor
Polyiso Insulation Performance in Cold Climates - GreenBuildingAdvisor
R- 2.9 , 0.75-in x 4-ft x 8-ft Faced Polystyrene Board Insulation Lowes.com
R- 2.9 , 0.75-in x 4-ft x 8-ft Faced Polystyrene Board Insulation Lowes.com
What Is Insulation R Value?
What Is Insulation R Value?

This matters most in cold climate zones. In IECC climate zones 5 through 8, some designers deliberately derate polyiso when calculating wall or roof assemblies, while others rely on the labeled LTTR and accept the seasonal penalty as part of the energy model. Either approach can pass review depending on the local jurisdiction, so confirm the expectation with your code official before finalizing thickness. Extruded polystyrene shows much less temperature sensitivity, which is one reason it remains popular for cold-climate exterior sheathing even though its baseline R-value per inch is lower.

Foil Facing and Moisture Resistance

Aluminum foil facers do double duty. On top of protecting the foam core, they act as a radiant barrier when installed facing an air space, blocking a portion of radiant heat transfer that would otherwise bypass the insulation. In a vented attic or a wall with a drainage plane, that reflective surface can add meaningful performance beyond the nominal R-value of the foam itself.

AD

Foil facers also slow vapor movement, which is why polyiso is often specified as part of a vapor-retarding strategy in mixed or cold climates. The catch is that a low-permeance facer can trap moisture if the assembly is not designed to dry in at least one direction. Pair polyiso with the right interior and exterior materials, and it performs beautifully; install it carelessly and you create a condensation sandwich.

How Polyiso Compares to Other Insulation Types

Choosing insulation is always a trade-off between R-value per inch, cost, moisture tolerance, fire performance, and ease of installation. Polyiso wins decisively on the first metric, but that advantage narrows or disappears in certain conditions. The table below gives a quick reference for common products at a mean temperature near 75 degrees Fahrenheit.

Insulation TypeTypical R-Value Per InchNotes
Polyiso (LTTR)R-5.6 to R-6.5Highest at moderate temps; loses performance in cold
Extruded Polystyrene (XPS)R-4.5 to R-5.0Excellent moisture resistance; good below grade
Expanded Polystyrene (EPS)R-3.8 to R-4.4Lowest cost rigid foam; vapor permeable
Closed-Cell Spray FoamR-6.0 to R-7.0Air sealing plus insulation in one step
Mineral Wool BoardR-3.7 to R-4.3Fire and sound benefits; moisture tolerant
Fiberglass BattR-3.1 to R-3.8Cheap but relies on perfect air sealing

Cost per installed R follows a similar pattern. Polyiso generally lands between EPS and spray foam on a dollars-per-R basis, and its thin profile can reduce framing, fasteners, and labor compared with thick layers of lower-density material. When you are retrofitting a wall where every half inch of depth counts, that density of performance is often worth the premium.

Where polyiso loses ground is in ground-contact and high-moisture applications. XPS and EPS tolerate wet conditions far better, and mineral wool shrugs off water entirely. Below-grade foundation insulation, exterior basement walls, and areas with chronic bulk water exposure are better served by those products even though their per-inch R-value is lower.

Polyiso Versus XPS and EPS

Compare a two-inch polyiso board at R-5.8 per inch against two-inch XPS at R-5.0 and two-inch EPS at R-4.0. The polyiso gives you roughly R-11.6, the XPS about R-10, and the EPS around R-8. In a mild or mixed climate, that polyiso advantage holds up across the seasons and makes it the clear winner for exterior continuous insulation on walls and roofs.

Move that same comparison to a cold climate and the gap narrows. Derated for cold service temperatures, polyiso might deliver closer to R-9.5 while XPS holds near R-9.5 as well, which suddenly makes the cheaper or more moisture-tolerant option more attractive. Run the numbers for your specific climate zone, orientation, and assembly before assuming polyiso is always the best answer.

Polyiso Versus Spray Foam and Mineral Wool

Closed-cell spray foam edges out polyiso on pure R-value per inch, typically landing between R-6.0 and R-7.0 depending on the formulation and manufacturer. That advantage comes with a much higher installed cost, the need for specialized equipment, and a curing period before the space can be occupied. Spray foam also air seals as it expands, which solves infiltration problems that rigid boards cannot address on their own.

Mineral wool boards sit at the opposite end of the spectrum, offering roughly R-3.7 to R-4.3 per inch. What they lack in thermal punch they make up for with fire resistance, sound dampening, and the ability to stay effective even when saturated with water. Many high-performance wall assemblies pair a polyiso exterior layer with mineral wool or fiberglass in the stud cavity, using each material where it performs best instead of forcing one product to do everything.

Getting the most out of polyiso comes down to matching the product to the assembly rather than chasing the biggest number on a spec sheet. Pull the LTTR from the manufacturer's data sheet, derate it if you build in a cold climate, verify that the facer type suits your vapor strategy, and keep water out of the details. Do those four things and the R-value per inch you install is the R-value per inch you keep for decades. If you are still deciding between two thicknesses or two products for a specific wall or roof, run the calculation with real numbers from your supplier before the order goes in.

AD