lennox furnace ignitor

Lennox Furnace Ignitor: Symptoms, Replacement & Buying Guide

By Laura Brown
AD

When a Lennox furnace stops producing heat, the Lennox furnace ignitor is often the first component homeowners and technicians suspect. This small but critical part is responsible for lighting the burners, and when it fails, the furnace may run its blower or inducer motor without ever producing warm air. Understanding how the ignitor works can save you time, money, and the frustration of a cold house.

A Lennox furnace ignitor is not a one-size-fits-all component. Depending on your furnace model, it may be a hot surface ignitor, a spark ignitor, or a specialized OEM part with specific voltage and mounting requirements. This guide covers how the ignitor functions, the most common failure symptoms, safe troubleshooting steps, and what to know before ordering a replacement.

Lennox Furnace Ignitor Basics: Function, Types, and Failure Signs

The ignitor is the component that starts the combustion process inside your Lennox furnace. In most modern Lennox systems, a hot surface ignitor, often called an HSI, uses electricity to heat a ceramic element until it glows bright orange or white. That intense heat then ignites the gas flowing from the burners, creating the flame that warms your home.

AD
"Lennox 74N47: High-Efficiency HSI Ignitor for Furnace Replacement"
"Lennox 74N47: High-Efficiency HSI Ignitor for Furnace Replacement"
Lennox 20256001 Igniter Assembly 70L55
Lennox 20256001 Igniter Assembly 70L55
Ignitor for Lennox Furnace | 17J57
Ignitor for Lennox Furnace | 17J57

Even though the ignitor is small, it depends on several other parts working correctly. The control board must send voltage, the pressure switch must prove proper draft, the gas valve must open at the right moment, and the flame sensor must confirm that ignition occurred. If any part of that sequence fails, the furnace may shut down or lock out, even if the ignitor itself is still functional.

How a Lennox Hot Surface Ignitor Works

When your thermostat calls for heat, the furnace control board begins a precise ignition sequence. The inducer motor starts to pull air through the heat exchanger, the pressure switch closes, and then the board sends voltage to the Lennox furnace ignitor. Most hot surface ignitors operate on 120 volts AC, but some models use different voltages, so the wiring diagram should always be consulted before testing or replacing one.

Lennox 56W19 Control Board
Lennox 56W19 Control Board
24L8501 | Lennox SureLight Furnace Control Board 50A62-121 24V
24L8501 | Lennox SureLight Furnace Control Board 50A62-121 24V
Reliable Furnace Flame Sensor Replacement For Lennox , HVAC Ignition Part Reliable Furnace Flame Sensor Replacement For Lennox , HVAC Ignition Part
Reliable Furnace Flame Sensor Replacement For Lennox , HVAC Ignition Part Reliable Furnace Flame Sensor Replacement For Lennox , HVAC Ignition Part

After receiving voltage, the ignitor warms up for roughly 15 to 30 seconds. Once it reaches ignition temperature, the gas valve opens and burners should light almost immediately. If the ignitor glows but no flame appears, the problem may be gas supply, a stuck gas valve, a dirty flame sensor, or a control board issue rather than the ignitor itself.

Hot Surface vs. Spark Ignition in Lennox Furnaces

Not every Lennox furnace uses the same ignition method. Older models may use a spark ignition system, which creates a high-voltage spark to light a pilot or burner. Spark systems often produce a repetitive clicking sound before ignition. Newer Lennox furnaces more commonly use a hot surface ignitor, which glows silently and looks like a small ceramic pencil or probe.

AD

The two systems are not interchangeable. A spark ignitor assembly includes an electrode and ignition control, while a hot surface ignitor is a resistance-heated ceramic component. If you are unsure which type your furnace uses, check the model and serial plate, then compare it with the wiring diagram or an OEM parts diagram for your specific Lennox furnace.

220V 350W Wood Pellet Furnace Igniter, Heating Furnace Ignition Rod, High Temperature Resistance,
220V 350W Wood Pellet Furnace Igniter, Heating Furnace Ignition Rod, High Temperature Resistance,
Tested🔥 Lennox 1012-83-9694a 100973-02 Furnace Control Board
Tested🔥 Lennox 1012-83-9694a 100973-02 Furnace Control Board
Copeland White-Rodgers Hot Surface Ignitor Silicon Carbide 767A-361 - The Home Depot
Copeland White-Rodgers Hot Surface Ignitor Silicon Carbide 767A-361 - The Home Depot
Supco SSN21 Furnace Ignitor for Lennox Armstrong 75M21 75M2101 95 Volt
Supco SSN21 Furnace Ignitor for Lennox Armstrong 75M21 75M2101 95 Volt
Lennox 40L81 Flame Sensor Kit
Lennox 40L81 Flame Sensor Kit
ad eBay | $71.99 | Protect Your Lennox Furnace with New Limit Switch | Heating, Cooling & Air |Press
ad eBay | $71.99 | Protect Your Lennox Furnace with New Limit Switch | Heating, Cooling & Air |Press

Lennox Furnace Ignitor Troubleshooting and Replacement Guide

Before testing or replacing any furnace component, safety must come first. Turn off the thermostat, shut off electrical power to the furnace at the breaker, and close the gas valve. Wait for the ignitor to cool completely because hot surface ignitors can remain extremely hot even after the furnace stops running. Once the power and gas are off, remove the burner access panel and locate the ignitor near the burners.

Inspect the ignitor for visible cracks, a broken tip, white chalky spots, or contamination from dust and debris. A cracked or brittle ignitor is a clear sign of failure. However, a furnace that will not heat can also have a faulty pressure switch, a blocked flue, a tripped limit switch, a failed inducer motor, or a bad control board. For that reason, troubleshooting should always look at the entire ignition sequence rather than assuming the ignitor is the only problem.

AD

Common Symptoms and Error Codes of a Bad Lennox Ignitor

One of the most obvious symptoms of a failing Lennox furnace ignitor is a furnace that tries to start but never produces flame. You may hear the inducer motor running and the control board clicking, but the burners do not light. In some cases, the ignitor does not glow at all. In other cases, it glows but fails to ignite the gas, which can point to a gas supply issue or a weak ignitor that is no longer reaching the correct temperature.

Many Lennox furnaces use diagnostic LED codes that flash a specific pattern when ignition fails. These codes can indicate ignition lockout, pressure switch faults, flame sensing problems, or high-limit trips. Because error codes vary by furnace model and control board, always check the diagnostic label inside the blower compartment. If the code points to ignition failure, the ignitor should be tested before replacing other parts.

Testing, Replacing, and Choosing the Right Lennox Ignitor

To test a hot surface ignitor, disconnect power and remove the ignitor from its bracket. Use a multimeter to measure resistance across the ignitor terminals. Many Lennox ignitors read roughly 40 to 200 ohms at room temperature, but the exact specification depends on the part number. An infinite or open reading usually means the ignitor has failed and must be replaced. If resistance is within range, check for proper voltage at the ignitor plug during a call for heat, but only attempt live voltage testing if you are comfortable and trained to do so safely.

AD

When replacing the part, choose an OEM Lennox ignitor or a verified compatible replacement that matches the voltage, connector type, mounting bracket, and physical length. Universal ignitors can work in some applications, but they often require modifications and may not last as long. Handle the new ignitor by its ceramic base or with clean gloves, because oils from your fingers can shorten its life. Parts typically cost between $30 and $100, while professional replacement often runs $150 to $400 depending on the model and labor rates.

If your Lennox furnace is struggling to light, testing the ignitor is one of the most practical first steps you can take. A careful inspection, a proper resistance check, and the correct replacement part can restore reliable heat without unnecessary guesswork. When you are unsure about gas components, electrical testing, or model compatibility, bringing in a licensed HVAC technician is the safest way to protect your system and your home comfort.

AD