insulation r value chart

Insulation R-Value Chart: The Ultimate Guide to R-Values and Thickness

By Nicole Lopez
AD

If you have ever stood in the insulation aisle of a home improvement store staring at a wall of pink batts, rigid foam boards, and bags of loose fill, you have probably noticed that nearly every package leads with a single number. That number is the R-value, and it is the closest thing the building industry has to a universal language for thermal performance. An insulation R-value chart takes those individual product ratings and organizes them into a format you can actually compare, whether you are choosing between blown cellulose and open-cell spray foam or trying to figure out how much depth you need in a cramped attic.

The trouble is that a chart can be misleading if you do not understand what it is measuring. R-values are determined under controlled laboratory conditions, while your walls and attic deal with real-world wind, moisture, temperature swings, and installation shortcuts. Knowing how to read an R-value chart and, just as importantly, knowing where its numbers stop being useful is what separates a well-insulated home from one that merely looks well insulated on paper.

How to Read an Insulation R-Value Chart

R-value stands for thermal resistance, and it measures how well a material slows the movement of heat through conduction. The higher the number, the better the material resists heat flow, so a product rated at R-6 per inch will outperform one rated at R-3 per inch of the same thickness. In a layered assembly like a wall, R-values add up: the sheathing, the cavity insulation, the rigid foam on the exterior, and even the interior drywall all contribute, which is why whole-wall R-values are always higher than the bare insulation rating alone.

AD
Insulation R-Value Chart: Complete Guide to Every Material (2026)
Insulation R-Value Chart: Complete Guide to Every Material (2026)
Is Your Home's Insulation Ready for Winter?
Is Your Home's Insulation Ready for Winter?
Home Insulation Buying Guide
Home Insulation Buying Guide

Almost every insulation chart you encounter uses one of two frames of reference. The first is R-value per inch, which tells you how efficiently a material performs given a fixed amount of space. The second is total R-value for a specific installed thickness, which is what actually matters for meeting code. A chart that only lists one of these two numbers is only half useful, so look for both before you commit to a product.

R-Value Per Inch vs. Total R-Value

R-value per inch is the metric that matters most in retrofit work, where the depth of a wall cavity or the headroom in an attic is fixed and you cannot simply add more material. Closed-cell spray foam, for example, delivers roughly R-6 to R-7 per inch, while standard fiberglass batts land closer to R-3 per inch. If your wall cavity is only 3.5 inches deep, that difference translates into a total of about R-21 to R-24 with closed-cell foam versus roughly R-13 to R-15 with fiberglass batts.

All About Insulation R-Values | The Home Depot
All About Insulation R-Values | The Home Depot
What is the Highest R-Value Insulation? (Ratings/Types/Charts)
What is the Highest R-Value Insulation? (Ratings/Types/Charts)
Insulation R-Values
Insulation R-Values

Total R-value is the number that appears in building codes and energy audits. A typical 2x6 wall frame with fiberglass batts reaches about R-19, and adding an inch of exterior rigid foam can push the assembly toward R-24 or higher. When you compare quotes from contractors, always ask whether the stated R-value refers to the insulation product alone or the complete assembly, because the gap between those two figures is often substantial.

The Difference Between R-Value and U-Factor

Windows, doors, and some insulation products are rated with U-factor instead of R-value, and mixing the two up is one of the most common mistakes homeowners make. U-factor measures how quickly heat moves through a material, so lower numbers are better. The two values are mathematical reciprocals: U-factor equals one divided by R-value. A window rated at U-0.30, for instance, has an effective R-value of about 3.3.

AD

This reciprocal relationship matters when you are comparing a window's performance to a wall's performance. It is tempting to see a wall at R-20 and a window at U-0.30 and assume the window is far worse than it is, but converting the U-factor makes the comparison honest. Modern triple-pane windows can reach effective R-values of 5 to 8, which is a dramatic improvement over the single-pane units found in older homes.

insulation value chart for various types of insulations and their uses, including insulation insulation
insulation value chart for various types of insulations and their uses, including insulation insulation
FAQ Insulation Values & Comparisons – Metric and Imperial
FAQ Insulation Values & Comparisons – Metric and Imperial
Best Online Poker Sites USA - Poker Bonuses Compared
Best Online Poker Sites USA - Poker Bonuses Compared
Best Practices for Double-Strapping the Roof | Benjamin Obdyke
Best Practices for Double-Strapping the Roof | Benjamin Obdyke
Insulation Buying Guide
Insulation Buying Guide
Insulation Calculator – Estimate Insulation Coverage, R-Value & Material Online
Insulation Calculator – Estimate Insulation Coverage, R-Value & Material Online

Insulation R-Value Chart by Material

Material choice drives the numbers on any R-value chart far more than brand or price. Fibrous insulations like fiberglass, mineral wool, and cellulose rely on trapped air pockets to slow heat transfer, which limits them to roughly R-3 to R-4 per inch. Foam insulations, whether sprayed or sold as rigid boards, use closed or open gas-filled cells and can reach R-4 to R-7 per inch depending on the chemistry.

Two materials with identical R-values per inch can behave very differently in practice, so the chart should be the starting point of your decision rather than the end of it. Air sealing ability, moisture tolerance, fire performance, and cost per installed R all vary widely, and some of those factors outweigh a small difference in thermal rating. The table below summarizes typical published values for the most common residential options.

AD

Fiberglass, Mineral Wool and Cellulose

Fiberglass is the most familiar option and comes in batts, rolls, and loose-fill form. Batts typically rate between R-2.9 and R-3.8 per inch, while blown-in fiberglass settles in around R-2.2 to R-2.7 per inch. Mineral wool, sold under brands like Rockwool and Thermafiber, holds a steadier R-3.0 to R-3.3 per inch and resists moisture and fire better than fiberglass, which makes it a strong choice for basements and exterior walls.

Tips for Reducing Insulation Labor Time and Costs on Commercial Jobs - Roofing
Tips for Reducing Insulation Labor Time and Costs on Commercial Jobs - Roofing
Home Insulation R-Value vs. Cost: What’s The Best To Buy?
Home Insulation R-Value vs. Cost: What’s The Best To Buy?
the diagram shows different insulation types for walls and ceilings, with instructions to choose which one is
the diagram shows different insulation types for walls and ceilings, with instructions to choose which one is
Rigid Insulation R Values (Chart w. EPS, XPX, ISO, Spray Foam)
Rigid Insulation R Values (Chart w. EPS, XPX, ISO, Spray Foam)

Cellulose, made largely from recycled newspaper treated with fire retardants, lands between R-3.1 and R-3.8 per inch when installed at the proper density. It performs well in attics because it conforms around obstructions and reduces air leakage, but it can settle over time if installed too loosely. For any loose-fill product, ask the installer for the installed density and the settled thickness, because both numbers directly affect the final R-value you actually receive.

Foam Boards and Spray Polyurethane Foam

Rigid foam boards are the champions of R-value per inch. Expanded polystyrene, usually white and bead-like, offers roughly R-3.8 to R-4.4 per inch. Extruded polystyrene, typically blue or pink, reaches R-4.5 to R-5.0 per inch, and polyisocyanurate boards can hit R-5.6 to R-6.5 per inch at room temperature. Spray polyurethane foam splits into open-cell, at about R-3.6 to R-3.9 per inch, and closed-cell, at R-6.0 to R-7.0 per inch.

AD

Polyiso deserves a special note because its R-value drops as temperatures fall, a phenomenon called thermal drift. At 25 degrees Fahrenheit, a polyiso board rated R-6.5 at 75 degrees may only deliver around R-5.5, which matters in cold climates where the exterior sheathing gets genuinely frigid. Closed-cell foam is the most expensive option per installed R but often wins on total performance because it also acts as an air barrier and a vapor retarder in a single application.

Insulation MaterialTypical R-Value Per InchCommon Form
Loose-fill fiberglassR-2.2 to R-2.7Blown-in
Fiberglass battsR-2.9 to R-3.8Batts and rolls
Mineral woolR-3.0 to R-3.3Batts and loose-fill
CelluloseR-3.1 to R-3.8Loose-fill
Open-cell spray foamR-3.6 to R-3.9Sprayed
Expanded polystyrene (EPS)R-3.8 to R-4.4Rigid board
Extruded polystyrene (XPS)R-4.5 to R-5.0Rigid board
PolyisocyanurateR-5.6 to R-6.5Rigid board
Closed-cell spray foamR-6.0 to R-7.0Sprayed

Recommended R-Values by Climate Zone and Assembly

Building codes translate insulation performance into minimum requirements based on where you live, and these thresholds are the practical target most homeowners should aim for. The International Energy Conservation Code divides the country into eight climate zones, from hot and humid Zone 1 in southern Florida to subarctic Zone 8 in interior Alaska. Each zone carries its own recommended R-values for ceilings, walls, floors, and basement walls.

Code minimums are a floor, not an ideal. Many energy professionals recommend exceeding them by 20 to 50 percent, especially in attics where adding insulation is inexpensive during new construction or a major renovation. Upgrading an attic from R-30 to R-60 often costs a few hundred dollars in materials and pays that back through lower heating and cooling bills within a handful of years.

Attics, Walls, Floors and Crawlspaces

Attics carry the highest recommended R-values because heat rises and because attic insulation is usually the cheapest per unit of R to install. In warm Zones 1 through 3, the code calls for roughly R-30 to R-49 in the ceiling. In Zones 4 through 8, that figure climbs to R-60. Above-grade wood-frame walls generally require R-13 to R-20 of cavity insulation, often combined with continuous exterior rigid foam that adds another R-5 to R-10 and breaks thermal bridging at the studs.

Floors over unconditioned spaces and crawlspace ceilings typically call for R-19 to R-30, while unvented crawlspaces should be insulated at the walls rather than the ceiling. Basement walls usually land between R-10 and R-15 of continuous insulation, and rim joists, the band of framing where the floor meets the foundation, are one of the most commonly overlooked spots in the entire house. Sealing and insulating rim joists with rigid foam or closed-cell spray foam is a low-cost upgrade with an outsized effect on comfort.

Why Real-World Performance Diverges from the Chart

Every R-value on a chart assumes a perfectly installed, gap-free, moisture-free material at a standard test temperature. Reality rarely cooperates. Compressing a fiberglass batt into a cavity that is too small can cut its effective R-value by 20 percent or more, and even a small gap around the edges allows air to bypass the insulation entirely. Studies consistently show that a sloppy R-19 installation can underperform a careful R-13 one.

Thermal bridging is the other silent culprit. Wood studs conduct heat roughly three to four times better than insulation, so a wall framed at 16 inches on center loses a meaningful portion of its rated R-value through the framing alone. Continuous exterior insulation, often called continuous insulation or ci, solves this by wrapping the entire assembly in an unbroken layer. Combining air sealing, proper installation, and continuous insulation will always beat simply stacking more batts on top of a leaky assembly.

Start with the chart, but finish with a plan. Identify your climate zone, measure the actual depth of your existing insulation, and check whether air sealing or thermal bridging is quietly undermining the R-value you already paid for. A few hours with a caulk gun and a flashlight in the attic often deliver more comfort per dollar than any single product on the shelf, and the chart simply tells you where to aim next.

AD