Generac 5734 200A Transfer Switch: Complete Guide, Specs & Buying Tips
Few names carry as much weight in the portable power world as the Generac 5734, a machine better known to most buyers as the GP5500. It earned that reputation the old-fashioned way: by starting when it was supposed to, running longer than expected, and asking for very little in return. Whether you are shopping the used market, trying to identify a unit already sitting in your garage, or comparing it against today's inverter-style options, understanding exactly what this generator offers is the first step toward making a smart decision.
This article breaks down the Generac 5734 from top to bottom, covering its engine and power ratings, its outlet configuration, how long it realistically runs on a tank of fuel, and what it takes to keep one alive for a decade or more. You will also find practical guidance on load management, maintenance intervals, and safe operation, plus an honest look at who this generator actually suits and where it falls short compared to newer designs.
Generac 5734 Specs and Design Overview
The Generac 5734 was built during an era when portable generators prioritized raw capability over gadgets, and that philosophy shows in every part of the machine. It is a conventional synchronous generator with a brushed alternator, a steel fuel tank, a full wrap-around tubular frame, and a control panel that keeps things refreshingly simple. There is no Bluetooth app, no automatic transfer switch compatibility, and no electronic fuel injection, just a mechanical machine designed to deliver alternating current whenever you pull the rope.
What makes the 5734 worth studying today is how well its numbers still hold up against modern competitors. A generator rated at 5,500 running watts and 6,875 starting watts covers an enormous range of household and jobsite demands, from a refrigerator, furnace blower, and a few lights during an outage to a circular saw, air compressor, or welder on a remote project. That power ceiling is the reason this model stayed in service for so many years and why used examples continue to sell quickly.
Engine and Power Output
At the heart of the Generac 5734 sits a 389cc Generac OHV engine with a cast iron cylinder sleeve, a design choice that pays dividends in longevity when the unit is maintained properly. The engine is air-cooled and splash-lubricated, which keeps the architecture simple and repairs inexpensive. A low-oil shutdown system protects the engine by killing the ignition before lubrication levels drop to a point where damage becomes permanent, a feature that has saved countless generators from an early death after a user forgot to check the dipstick.
That engine drives an alternator producing 120 and 240 volts, giving the unit true dual-voltage capability rather than the single-voltage output found on many budget models. The 6,875 starting watts handle the inrush current demanded by motors and compressors, while the 5,500 running watts cover the steady-state load once those devices are spinning. In practical terms, that means you can start a well pump or a large refrigerator without tripping the breaker, provided you stagger your startup sequence rather than switching everything on at once.
Outlet Panel, Controls, and Fuel System
The control panel on the 5734 is straightforward but thoughtfully laid out. It includes a 120/240-volt 30-amp locking receptacle, two 120-volt 20-amp household outlets, and a 12-volt DC outlet for charging automotive-style batteries. Each circuit is protected by its own push-to-reset breaker, so a fault on one leg does not take down the entire panel. A master rocker switch controls ignition and fuel flow, and the fuel shutoff valve lets you run the carburetor dry before storage, which is one of the simplest ways to prevent gummed-up jets and hard starting next season.
The fuel tank holds 7.2 gallons of gasoline, a capacity that places this generator firmly in the full-day runtime category rather than the two-hour sprint class. A built-in fuel gauge on the tank cap lets you check levels at a glance, and the tank filler neck is wide enough to accept a standard jerry can spout without spilling half the fuel down the side of the unit. Combine that capacity with the 389cc engine's moderate consumption and you get a machine that can carry a household through an extended outage without constant refueling runs.
Real-World Performance of the Generac GP5500
Spec sheets tell you what a generator should do; ownership tells you what it actually does. The Generac 5734 has been used for years in garages, on farms, at campsites, and behind food trucks, and the feedback from those environments paints a consistent picture. It starts reliably with a firm pull, holds voltage well under fluctuating loads, and tolerates the kind of abuse that comes with being dragged across gravel and left in a shed for eight months.
That said, this is a conventional generator, and conventional generators come with trade-offs. It is louder than an inverter unit, heavier than a modern dual-fuel model of similar output, and it produces total harmonic distortion levels that make it a poor match for sensitive electronics like laptops and televisions without a surge protector or line conditioner. Understanding those limitations before you buy keeps expectations realistic and prevents disappointment.
Runtime, Fuel Consumption, and Load Planning
Generac rates the 5734 at roughly ten hours of runtime at half load, which works out to around 2,750 watts of continuous demand. In practice, most households running a refrigerator, a furnace fan, a few LED lights, and a router draw considerably less than that, so real-world runtime during an outage often exceeds the published figure. Push the generator toward its 5,500-watt ceiling with a space heater and a microwave running simultaneously and you can watch that runtime shrink toward five or six hours per tank.
Load planning is therefore the single most valuable skill an owner can develop. Write down the running watts and starting watts of everything you intend to power, total the running figures, and make sure the largest motor-driven appliance gets started first or on its own. Rotating high-draw appliances, such as running the well pump in the morning and the space heater in the evening, stretches both fuel and engine life while keeping the generator in its most efficient operating band.
Noise, Portability, and Daily Usability
Noise output on the 5734 hovers around 72 decibels at close range, which is loud enough to annoy a neighbor across a suburban fence line. Situating the unit behind a garage, using a longer heavy-gauge extension cord to move it away from living spaces, and avoiding late-night operation all help. For rural properties and jobsites, the noise is rarely an issue, but anyone in a densely packed neighborhood should plan accordingly or consider an inverter generator instead.
Portability is a mixed bag. The unit weighs roughly 189 pounds dry, so it is not something you carry up a flight of stairs. The included wheel kit and folding handle make it manageable on flat ground, and the never-flat wheels handle grass and gravel without sinking. If you need to move it regularly across rough terrain, budget for a helper or a small ramp, because the weight is real and the frame, while sturdy, is not designed to be lifted by two people indefinitely.
Maintenance, Safety, and Ownership Considerations
A generator is only as good as the maintenance schedule behind it, and the Generac 5734 rewards owners who follow a simple routine. Oil changes, air filter cleanings, spark plug replacements, and fuel system care form the backbone of long-term reliability. Skip them and you will be diagnosing a no-start condition in the middle of a storm; follow them and the machine will likely outlast several of the appliances it powers.
Safety deserves equal attention because generators combine three hazards in one package: carbon monoxide, electricity, and flammable fuel. Every owner should understand placement rules, grounding requirements, and the dangers of backfeeding a home through a dryer outlet. These are not abstract concerns, and a few minutes of planning prevents the scenarios that make the news every winter.
Routine Maintenance Schedule
Generac recommends an oil change after the first five to eight hours of break-in operation, then every fifty hours or annually, whichever comes first. Use the viscosity specified for your climate, and never overfill, since excess oil can foam and reduce lubrication. The air filter should be checked every twenty-five hours and cleaned or replaced as needed, while the spark plug typically lasts around one hundred hours before it needs gapping or replacement. A foam pre-filter, if equipped, can be washed in soapy water and re-oiled rather than replaced.
Fuel system maintenance separates the generators that start on the first pull from the ones that end up on a repair bench. Treat every tank of gas with a stabilizer, run the carburetor dry using the fuel shutoff valve before any storage period longer than a month, and never leave ethanol-blended fuel sitting in the bowl through an entire off-season. If the unit has been stored for more than a year, drain and replace the fuel entirely rather than trying to burn through stale gas.
Safe Operation and Storage
Never run the Generac 5734 indoors, in a garage, in a carport, or anywhere near an open window or intake vent. Carbon monoxide is colorless and odorless, and generators produce it in lethal quantities. Place the unit outdoors on a dry, level surface at least twenty feet from any structure, with the exhaust pointed away from doors and windows. Battery-powered CO detectors inside the home are a cheap insurance policy regardless of how careful you are.
Store the generator with the fuel valve closed, the tank either completely full with stabilized fuel or completely empty, and the spark plug wire disconnected if children have access to the area. Cover it to keep dust and moisture out of the alternator vents, but avoid sealing it so tightly that condensation becomes trapped inside. If you live in a region with hard freezes, store the unit where temperatures stay above freezing to protect the battery on models so equipped and to make cold starts easier.
Is the Generac 5734 Still Worth Buying?
The 5734 has been discontinued and replaced by newer GP-series models, which means your options are limited to used listings, leftover inventory, and refurbished units. That changes the calculus considerably. The value proposition now hinges on condition, price, and parts availability rather than factory warranty coverage, so a careful inspection before purchase matters far more than it would with a new unit.
Parts availability remains solid because the 389cc engine platform and many of the alternator components were shared across multiple Generac models for years. Carburetors, ignition coils, voltage regulators, recoil assemblies, and wheel kits are all findable through aftermarket suppliers. That shared architecture is a genuine advantage, and it is one of the main reasons a well-kept 5734 can still make sense as a secondhand purchase.
Who This Generator Suits Best
The ideal owner is someone who needs dependable 240-volt capability for well pumps, sump pumps, or small welders, and who is comfortable with manual maintenance tasks like oil changes and carburetor care. Rural homeowners, contractors working off-grid, and anyone who wants a straightforward machine without electronic modules to fail are all well served. The 5734's lack of complexity is not a shortcoming in these contexts; it is the feature.
It suits apartment dwellers, tailgaters, and anyone who needs whisper-quiet power for sensitive electronics far less well. Those users should look at inverter generators in the 2,000 to 3,500-watt range, which are lighter, quieter, and produce cleaner power. Purchasing the 5734 for a use case it was never designed for leads to frustration, especially once you account for fuel consumption and noise.
Alternatives and Where to Find Support
If you are comparing the 5734 against current options, the closest new equivalents are the Generac GP5500 successors, the Champion 100519, and the DuroMax XP5500EH, all of which offer similar output with updated features like electric start or dual-fuel capability. Inverter alternatives such as the Honda EU7000iS deliver cleaner power and dramatically lower noise, but at a price point that can be four times higher. Match the tool to the job rather than chasing specifications.
For support, Generac's website still hosts owner's manuals and parts diagrams for discontinued models, and independent repair shops that service small engines can handle nearly anything the unit needs. Online forums dedicated to generators are another underrated resource, particularly for troubleshooting carburetor issues and voltage regulation problems. Keeping a printed copy of the manual with the unit saves a lot of guesswork when something goes wrong at an inconvenient hour.
If you already own a Generac 5734, the smartest move is to give it a proper service before the next storm season arrives: fresh oil, a clean filter, a new plug, stabilized fuel, and a thirty-minute test run under load. If you are shopping for one, bring a multimeter, check the oil, ask how it was stored, and start it cold before any money changes hands. A machine that has been cared for will return the favor for years, and a little diligence now beats scrambling for power when everyone else is doing the same.